← Hose Systems
Test & laboratory / QDM

Hose test system

A guarded test-station concept with a horizontal specimen area and operator controls.

Enquire about this machine

Machine & device catalog · Configuration agreed per project

Representative QDM hose test system design visualization
Hose test system — studio design view; display indications are illustrative, not equipment ratings · Representative design visualization
The application

What the equipment is for.

The hose test station is developed around a specimen held inside a guarded horizontal working area. The design focuses on specimen connections, access and an operator-controlled test sequence. The test medium, pressure, acceptance method and protective measures must be defined for the actual hose and test procedure.

Applications to discuss

  • Application-specific hose checks
  • R&D test fixtures
  • Production quality-control stations
Developed around the requirement

Configure the working process.

01

Specimen and connections

Define hose dimensions, fittings, connection access and specimen support.

02

Test circuit

Agree the medium, test conditions, measurement method and required result records.

03

Protective station

Develop containment, access control and the agreed pressure-release and operating arrangements.

Materials, dimensions, operating range, output, controls and delivery scope are confirmed in the project proposal.

Application & engineering guide

Defining a hose test before developing the station

Use these notes to define the application before choosing the final equipment configuration.

Working principle

A hose test station connects and supports a specimen while an agreed procedure is performed. Pressure holding, leak checking and destructive testing are different tasks. Pressure-decay instruments detect leakage by observing a pressure change under defined conditions; that principle does not establish the test method or pressure rating of the illustrated QDM station.

Configuration decisions

Specify the hose construction, fittings, test medium and acceptance requirement. Flexible specimens and their connection volumes should be considered when selecting a measurement method. The fixture must suit the connection and loading procedure, while containment, isolation and pressure release follow the actual test conditions. Numerical indications in a representative visualization are not equipment ratings.

Planning the first build

The first engineering stage should define the circuit, specimen support and operator sequence together. Agree calibration or reference checks, the treatment of a failed specimen and whether results are recorded. Use the stated procedure and representative hose assemblies for acceptance. QDM can scope an R&D fixture or a production check station once these requirements and protective measures have been reviewed.

Project-specific technical parameters

Values to define before the build.

The table identifies the reference arrangement and the values to agree for your application.

Defining a hose test before developing the station — configuration parameters
ParameterConfiguration / valueConfirm before manufacture
Test objectiveLeak, holding or other agreed procedureSupply the required method
Hose envelopeDefined length and diameter in mmInclude fittings and bend limits
Test mediumApplication-specific gas or liquidConfirm compatibility and handling
Test pressureSpecified per project in bar or kPaAgree rated circuit and containment
MeasurementSelected for the procedureDefine units and acceptance limit
ConnectionsSpecimen-specific fixturesReview loading and sealing method
Results and releaseRecords and depressurisation as scopedDefine failure and unloading sequence

These products are customizable. Configuration values and images are indicative and may change with the application. Final dimensions, components, controls and performance requirements are confirmed in the agreed project specification.

For supplied QDM equipment

Warranty & ongoing support.

Machine warranty

One year from commissioning.

QDM supplies equipment with a standard one-year machine warranty, starting from commissioning.

Component warranty

Manufacturer’s terms.

Purchased components are covered under the relevant manufacturer’s warranty terms. Two-year component coverage applies where provided by the manufacturer; coverage and start dates follow those terms.

Extended cover & maintenance

Plan the support you need.

Extended warranty and maintenance agreements can be arranged for the project. Coverage, duration, service responsibilities and commercial terms are agreed in the contract.

The quotation and contract define the equipment covered, the applicable warranty terms and the agreed service arrangements.

For a useful first discussion

Tell us about your application.

Send the hose and fittings, test medium, required procedure, test conditions and acceptance criteria.

Email us about this machine
Related machines & devices

Explore another configuration.

Browse the catalog
QDM orbital shaker concept with a low octagonal base, twelve sample bottles and left control pod
Test & laboratory

Laboratory orbital shaker

An orbital shaker development for viscous liquids, with the vessel arrangement and mixing requirements defined for each application.

QDM inline hose test system with enclosed process area and conveyor · generated design visualization
Test & laboratory

Inline hose test station

A hose test module with handling interfaces for a connected production process.

Representative QDM dosecore dosing platform family group
Dosing & filling

DoseCore product family

DuDose · GaDose · SoDose

A modular device family for liquid dosing, filling and application-specific mixing.

Kataloglar / Catalogues

WhatsApp